Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1385753

RESUMEN

ABSTRACT: This study aimed to compare the effect of four irrigation solutions for post space cleaning on the bond strength between glass fiber post and root dentine. Forty bovine roots were root-filled and randomly divided into four groups (n=10), according to the irrigation solution: CG (Control Group): saline solution; SH (Sodium Hypochlorite Group); CLX (Chlorhexidine group) and EDTA (ethylenediaminetetraacetic acid group). Specimens were submitted to mechanical aging and push-out test. Statistical analysis (ANOVA two-way and Tukey test; p<0.05) was performed. A stereomicroscope was used for failure mode classification. EDTA showed higher bond strength values, differing statistically from SH and CG (p<0.05). Adhesive failure between dentin and resinous cement was predominant, followed by mixed failures. SEM images showed pronounced smear layer removal in the EDTA group. 17 % EDTA was better than other solutions for cleaning of post space when using glass fiber posts.


RESUMEN: Este estudio tuvo como objetivo comparar el efecto de cuatro soluciones de irrigación para la limpieza del espacio del poste sobre la fuerza de unión entre el poste de fibra de vidrio y la dentina radicular. Se rellenaron cuarenta raíces bovinas y se dividieron aleatoriamente en cuatro grupos (n = 10), según la solu- ción de riego: CG (Grupo Control): solución salina; SH (Gru- po de hipoclorito de sodio); CLX (grupo clorhexidina) y EDTA (grupo ácido etilendiaminotetraacético). Las muestras se sometieron a una prueba de envejecimiento mecánico y de expulsión. Se realizó análisis estadístico (ANOVA bidireccional y prueba de Tukey; p <0,05). Se utilizó un microscopio estereoscópico para la clasificación del modo de falla. EDTA mostró valores de fuerza de unión más altos, difiriendo estadísticamente de SH y CG (p <0,05). Pre-dominó la falla adhesiva entre dentina y cemento resinoso, seguida de fallas mixtas. Las imágenes SEM mostraron una eliminación pronunciada de la capa de frotis en el grupo de EDTA. El EDTA al 17 % fue mejor que otras soluciones para la limpieza del espacio de los postes cuando se utilizan postes de fibra de vidrio.

2.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1008364

RESUMEN

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Asunto(s)
Tomografía con Microscopio Electrónico , Resistencia Flexional , Ácido Fluorhídrico
3.
J Mech Behav Biomed Mater ; 81: 173-177, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29525667

RESUMEN

The aim of this study was compare the effect of two in vitro ageing protocols to intraoral aging on the flexural strength of a lithium disilicate (LD) ceramic bars with clamped ends. After polishing and crystallization, the both ends of the bars were cemented to a metallic device and subjected to mechanical cycling, thermomechanical cycling, or intraoral ageing. Ten volunteers used an intraoral device - similar to an occlusal splint with a balanced contact condition on the occlusal surface of the ceramic bar - during 8 h night time / 30 days. Both in vitro and intraoral ageing decreased the flexural residual strength of LD, with the lowest values obtained after intraoral ageing. Thus, the in vitro ageing protocols tested in this study revealed to be less deleterious than intraoral ageing of LD.


Asunto(s)
Porcelana Dental , Resistencia Flexional , Ensayo de Materiales , Cerámica , Factores de Tiempo
4.
Braz. dent. sci ; 21(2): 150-156, 2018. ilus, tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-906051

RESUMEN

Objective: This research aimed to verify the performance of thermally activated acrylic resin (TAAR) combined with a mix of glass and aramid fibers and/or composite resin of indirect use by a tree point bending test. Material and Methods: Ten samples, with 65 x 10 x 2.5 mm, were prepared for each group (n = 10): CO, control of only TAAR; CR, in which an 60 mm indirect composite resin was polymerized together with the acrylic resin during the thermo-polymerization cycle; SS, in which ceramic glass mixed with aramid fibers cut 60 mm in length were incorporated into the samples; and SC, in which the same fibers were incorporated with addiction of the indirect composite resin. A three point flexural strength test was performed with a universal testing machine with a load of 50KgF at a speed of 5 mm/min in the center of the samples supported by a suitable device. The reinforced face was placed to the tensile side. The statistical one way ANOVA and Tukey tests were made with a significance level of 95%. Results: The mean value for the CO was 60,27 ± 24,18 MPa, for CR it was 38,39±12,75 MPa, for SS it was 79,97±12,75 Mpa and for CS it was 32,40±9,05 MPa. Conclusion: The use of glass and aramid fibers at the base of a TAAR increased the three-point flexural strength, however when indirect composite resin was incorporated, a significant drop of this mechanical property was observed. (AU)


Objetivo: Esta pesquisa teve como objetivo verificar o desempenho de uma resina acrílica ativada termicamente (RAAT) combinada com uma mistura de fibras de vidro e aramida e / ou resina composta de uso indireto por um teste de flexão de três pontos. Material e Métodos: Foram preparadas dez amostras, com 65 x 10 x 2,5 mm, para cada grupo (n = 10): CO, controle com apenas RAAT; CR, em que uma resina composta indireta de 60 mm com polimerizada em conjunto com a resina acrílica durante o ciclo de termopolimerização; SS, em que o vidro cerâmico misturado com fibras de aramida cortadas com 60 mm de comprimento foi incorporado nas amostras; e SC, nas quais as mesmas fibras foram incorporadas em conjunto com a resina composta indireta. O teste de resistência à flexão de três pontos foi realizado em uma máquina de teste universal com uma carga de 50 KgF a uma velocidade de 5 mm/min no centro das amostras suportadas por um dispositivo adequado. A face reforçado foi colocado no lado da tração. Os testes estatísticos one-way ANOVA e Tukey foram feitos com um nível de significância de 95%. Resultados: O valor para o CO foi de 60,27 ± 24,18 MPa, para CR foi de 38,39 ± 12,75 MPa, para SS foi de 79,97 ± 12,75 Mpa e para CS foi de 32, 40 ± 9,05 MPa. Conclusão: o uso de fibras de vidro e aramida na base de uma RAAT aumentou a resistência à flexão de três pontos, no entanto, quando a resina composta indireta foi incorporada, observou-se uma queda significativa dessa propriedade mecânica (AU)


Asunto(s)
Resinas Acrílicas , Resinas Compuestas , Dentadura Completa
5.
Braz. dent. sci ; 19(2): 139-144, 2016. ilus
Artículo en Inglés | LILACS | ID: lil-788620

RESUMEN

Clinicians can find patients with one mandibular remaining tooth, and it is difficult to decide if the tooth has to be removed. When a clinician decides to maintain the tooth, it is common to question the masticatory load distribution divided between the tooth and implant. This paper reports a clinical case of patient with an implant/tooth-supported overdenture and elucidates the masticatory efficiency by electromyography activity analysis. The objective of this case report was to describe a clinical case of a patient with an implant/tooth-supported overdenture and to discuss the muscle response to this treatment. Electrical activities of the masseter and anterior temporal surfaces at maximum voluntary contraction were evaluated by electromyography during pre-treatment, immediately post-treatment,15 and 60 days after installation. When patienthas one remaining tooth in good condition, theimplant/tooth-supported overdenture can be recommended, to preserve the periodontal ligament and proprioception, and to minimize bone loss. Electromyography analysis showed that implant/tooth-supported overdenture is a viable treatment alternative, in muscular stand point, when the patient has a remaining tooth with good osseous support...


Os dentistas podem encontrar casos em que o paciente possui apenas um dente mandibular remanescente,sendo difícil decidir se o dente deverá ser extraído. Quando o clínico decide manter este dente, é comum surgirem dúvidas sobre como ocorre a distribuição da carga mastigatória em próteses suportadas por dente e implante. Este artigo relata a resposta muscular por meio de atividade eletromiográfica de um paciente reabilitado com uma prótese inferior implantodentossuportada. O objetivo deste artigo foi descrever este caso clínico e discutir a resposta musculatória neste tipo de tratamento. As atividades eletromiográficas dos músculos massetere temporal anterior superficial foram avaliadas durante o pré-tratamento, imediatamente após a instalação da prótese, 15 e 60 dias pós-tratamento.Foi verificado que quando o paciente tem um dente remanescente em condição de ser mantido, a prótese implantodentossuportada pode ser recomendada como tratamento, para preservação do ligamento periodontal e da propriocepção, e para minimizar a perda óssea. A análise eletromiográfica demonstrou que a prótese implantodentossuportada é uma alternativa viável de tratamento, do ponto de vista muscular, quando o paciente possui um dente remanescente com suporte ósseo adequado...


Asunto(s)
Humanos , Implantación Dental , Prótesis e Implantes
6.
São José dos Campos; s.n; 2015. 109 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-867606

RESUMEN

Este trabalho teve como objetivos: avaliar a variação térmica que ocorre em ambiente bucal para predizer a quantidade e duração das variações de temperatura por dia, a temperatura máxima e mínima encontrada na cavidade oral e sugerir um novo protocolo de ciclagem térmica baseado nestas informações; e comparar os resultados de resistência de união após várias formas de envelhecimento. Para tal, foi instalado um sensor térmico wireless no palato de um aparelho parcial removível de seis voluntários, e estes foram monitorados durante três dias para desenvolvimento de um novo protocolo de ciclagem térmica. Após esta etapa, 40 blocos de cerâmica feldspática foram cimentados entre si (N=20), divididos em cinco grupos (n=4) e cortados em fatias. As fatias foram submetidas aos seguintes tipos de envelhecimento: C, teste imediato (sem envelhecimento); A, armazenagem em água por 30 dias; E, protocolo de ciclagem térmica experimental desenvolvido neste estudo; CIB, ciclagem intra-bucal; e ISO, protocolo de ciclagem térmica estabelecido pela norma ISO 11405 (2003). As fatias foram cortadas em palitos, os quais foram submetidos ao teste de microtração. A análise de falha foi realizada com o auxílio de um estereomicroscópio. A temperatura máxima encontrada foi de 47,59 ̊C, a mínima foi de 13,11 ̊C. A média de temperatura diária manteve-se entre 34 ̊C e 36 ̊C. A média de variação de temperatura por dia foi de 5,3 vezes, com duração média de 183 s. Os grupos A, CIB, E apresentaram valores de resistência de união estatisticamente menor que o grupo C (p-valor=0,0002), sendo semelhantes entre si. O grupo ISO foi semelhante aos grupos C e CIB. O modo de falha mais encontrado para todos os grupos foi do tipo mista. Conclui-se que ocorrem em média 6 variações térmicas por dia, com duração de 180 segundos. O protocolo de ciclagem térmica sugerido pela ISO não foi capaz de reduzir a resistência de união. A ciclagem experimental utilizada no E, de 180 ciclos térmicos de temperatura ...


This study aimed to evaluate the thermal variation that occurs in the oral environment; predicted the number of thermal cycles and temperature variation which occurs during certain time periods and compared the results of the bond strength of ceramic and luting agent after different aging protocols. For this purpose, six volunteers used a removable device with wireless thermal sensor and they were monitored for three days, to develop a new thermal cycling protocol. After this step, 40 feldspathic ceramic blocks were cemented together with a resin luting agent (N = 20), divided into five groups (n = 4) and cut into slices. Aging of the slices were: C, immediate test (without aging); A, storage in water for 30 days; E, thermal cycling experimental protocol developed in this study; CIB, storage of the slices in mouth for 30 days; and ISO, thermal cycling protocol established by ISO 11405 (2003). The slices were cut into sticks for microtensile test. The failure analysis were performed in a stereomicroscope. Maximum temperature observed was 47.59 ̊C, the lowest temperature was 13.11 ̊C. The average daily temperature is between 34 ̊C and 36 ̊C. The average temperature change per day was 5.3 times, with an average duration of 183 s. A, CIB, and E groups showed strength values statistically lower than C group (p-value = 0.0002), and they were similar among them. The ISO group was similar to the groups C and IB. The failure type most commonly found for all groups was mixed mode. It concluded that occurs daily 6 temperature variations, with duration of 180 seconds. The ISO thermocycling protocol did not reduce the bond strength. The experimental cycling used in E, 180 thermal cycles with a temperature range of 50 ̊C and 10 ̊C for 180 seconds each and 36 ̊C intermediate baths was able to accelerate the degradation process of bond between ceramic and cement that occurred during storage in water for 30 days


Asunto(s)
Cerámica , Materiales Dentales , Resistencia a la Tracción
7.
São José dos Campos; s.n; 2015. 109 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-870210

RESUMEN

Este trabalho teve como objetivos: avaliar a variação térmica que ocorre em ambiente bucal para predizer a quantidade e duração das variações de temperatura por dia, a temperatura máxima e mínima encontrada na cavidade oral e sugerir um novo protocolo de ciclagem térmica baseado nestas informações; e comparar os resultados de resistência de união após várias formas de envelhecimento. Para tal, foi instalado um sensor térmico wireless no palato de um aparelho parcial removível de seis voluntários, e estes foram monitorados durante três dias para desenvolvimento de um novo protocolo de ciclagem térmica. Após esta etapa, 40 blocos de cerâmica feldspática foram cimentados entre si (N=20), divididos em cinco grupos (n=4) e cortados em fatias. As fatias foram submetidas aos seguintes tipos de envelhecimento: C, teste imediato (sem envelhecimento); A, armazenagem em água por 30 dias; E, protocolo de ciclagem térmica experimental desenvolvido neste estudo; CIB, ciclagem intra-bucal; e ISO, protocolo de ciclagem térmica estabelecido pela norma ISO 11405 (2003). As fatias foram cortadas em palitos, os quais foram submetidos ao teste de microtração. A análise de falha foi realizada com o auxílio de um estereomicroscópio. A temperatura máxima encontrada foi de 47,59 ̊C, a mínima foi de 13,11 ̊C. A média de temperatura diária manteve-se entre 34 ̊C e 36 ̊C. A média de variação de temperatura por dia foi de 5,3 vezes, com duração média de 183 s. Os grupos A, CIB, E apresentaram valores de resistência de união estatisticamente menor que o grupo C (p-valor=0,0002), sendo semelhantes entre si. O grupo ISO foi semelhante aos grupos C e CIB. O modo de falha mais encontrado para todos os grupos foi do tipo mista. Conclui-se que ocorrem em média 6 variações térmicas por dia, com duração de 180 segundos. O protocolo de ciclagem térmica sugerido pela ISO não foi capaz de reduzir a resistência de união. A ciclagem experimental utilizada no E, de 180 ciclos térmicos de temperatura...


This study aimed to evaluate the thermal variation that occurs in the oral environment; predicted the number of thermal cycles and temperature variation which occurs during certain time periods and compared the results of the bond strength of ceramic and luting agent after different aging protocols. For this purpose, six volunteers used a removable device with wireless thermal sensor and they were monitored for three days, to develop a new thermal cycling protocol. After this step, 40 feldspathic ceramic blocks were cemented together with a resin luting agent (N = 20), divided into five groups (n = 4) and cut into slices. Aging of the slices were: C, immediate test (without aging); A, storage in water for 30 days; E, thermal cycling experimental protocol developed in this study; CIB, storage of the slices in mouth for 30 days; and ISO, thermal cycling protocol established by ISO 11405 (2003). The slices were cut into sticks for microtensile test. The failure analysis were performed in a stereomicroscope. Maximum temperature observed was 47.59 ̊C, the lowest temperature was 13.11 ̊C. The average daily temperature is between 34 ̊C and 36 ̊C. The average temperature change per day was 5.3 times, with an average duration of 183 s. A, CIB, and E groups showed strength values statistically lower than C group (p-value = 0.0002), and they were similar among them. The ISO group was similar to the groups C and IB. The failure type most commonly found for all groups was mixed mode. It concluded that occurs daily 6 temperature variations, with duration of 180 seconds. The ISO thermocycling protocol did not reduce the bond strength. The experimental cycling used in E, 180 thermal cycles with a temperature range of 50 ̊C and 10 ̊C for 180 seconds each and 36 ̊C intermediate baths was able to accelerate the degradation process of bond between ceramic and cement that occurred during storage in water for 30 days.


Asunto(s)
Cerámica , Materiales Dentales , Resistencia a la Tracción
8.
In. Miyashita, Eduardo; Pellizzer, Eduardo Piza; Kimpara, Estevão Tomomitsu. Reabilitação oral contemporânea baseada em evidências científicas. Nova Odessa, Napoleão editora, jun. 2014. p.272-311, ilus, tab. (BR).
Monografía en Portugués | LILACS, BBO - Odontología | ID: lil-715169
9.
São José dos Campos; s.n; 2012. 120 p. ilus, tab, graf.
Tesis en Portugués | BBO - Odontología | ID: biblio-866962

RESUMEN

O objetivo deste estudo foi avaliar a resistência à fratura de coroas cerâmicas à base de dissilicato de lítio (IPS e.max CAD) submetidas a neutralização do precipitado do ácido fluorídrico (HF) associada ao banho ultrassônico, e envelhecidas por meio de ciclagem termomecânica. Quarenta molares humanos receberam um preparo convencional para coroa total após terem sido incluídos em um padrão de poliuretano com a simulação do ligamento periodontal. Após escaneamento digital dos preparos, os blocos cerâmicos foram usinados pelo sistema CAD/CAM para obtenção das coroas. As mesmas foram distribuídas nos grupos conforme o tratamento de superfície a saber: Grupos 1 e 3 - HF + silano; Grupos 2 e 4 - HF + neutralização do precipitado do ácido fluorídrico + banho ultrassônico + silano. As coroas foram cimentadas com cimento resinoso dual e os espécimes dos grupos 3 e 4 foram submetidos à ciclagem termomecânica (5 / 55 °C / 60 s enquanto ocorria 1.200.000 ciclos mecânicos de 4 Hz com carga de 100 N). As amostras foram submetidas ao ensaio de compressão, com carga aplicada no centro da face oclusal da coroa até a fratura. A análise das fraturas foi realizada macroscopicamente (método de Burke) e em um Microscópio Eletrônico de Varredura. Os dados de resistência a fratura foram submetidos ao teste estatístico de análise de variância dois fatores. Não houve diferença estatística entre os grupos estudados, independente da realização de ciclagem termomecânica ou de tratamento de superfície pós condicionamento proposto (p-valor = 0,8409). A maioria das falhas foi associada com a fratura do remanescente dentário, sendo que a origem da fratura estava localizada na superfície de cimentação. Foi concluído que a resistência à fratura de coroas cerâmicas para dentes posteriores a base de dessilicato de lítio não é influenciada pela associação entre neutralização e banho ultrassônico,e a ciclagem termomecânica utilizada neste estudo não levou a fragilização da ...


The aim of this study was to evaluate the fracture resistance of lithium disilicate ceramic crowns (IPS e.max) subjected to neutralization of hydrofluoric acid (HF) associated with ultrasonic bath and aged by thermomechanical cycling. Forty human molar were prepared to receive afull crown after being included in a standard polyurethane with a simulationof the periodontal ligament. After the digital scanning of the prepared teeth, ceramic blocks were machined by CAD / CAM system to obtain the crowns. Then, they were distributed in groups according to surface treatment as follows: Groups 1 and 3 - HF + silane; Groups 2 and 4 - HF +neutralization + ultrasonic bath + silane. The crowns were cemented withdual-resin cement and the specimens of groups 3 and 4 were submitted to thermomechanical cycling (5 / 55 ° C for 60 s while the mechanical cyclingof 1.200.000/ 4 Hz /100 N is occurring). Subsequently, the specimens were subjected to a mechanical test, with a compressive load applied atthe center of the crown's occlusal surface until fracture. The fractograpy analyses was performed macroscopically (Burke method) and in aScanning Electron Microscope. The values of fracture resistance weresubmitted to a statistical test ANOVA two factors. There was no statisticaldifference between the groups, regardless of surface treatment orthermomechanical cycling (p-value = 0,8409). Most of the failures were associated with tooth remaining fracture, and the origin of the fracture was located on the cementation surface. It was conclude that the fracture resistance of lithium disilicate posterior ceramic crowns is not influencedby the association between neutralization and ultrasonic bath, and the thermo mechanical cycling used in this study did not lead to weakening ofthe ceramic


Asunto(s)
Humanos , Cerámica , Coronas , Ciencia de los Materiales , Ácido Fluorhídrico
10.
Artículo en Portugués | LILACS | ID: biblio-964430

RESUMEN

Introdução: A saliva humana tem sido amplamente utilizada para quantificar biomarcadores com finalidade científica e de diagnóstico, pois sua coleta é simples, não-invasiva e livre de estresse. O Salivette é o dispositivo de coleta de saliva mais empregado, devido à sua praticidade e aceitação pelo paciente, entretanto é desconhecida a influência de sua versão de poliéster nas análises das concentrações salivares de algumas substâncias. Objetivo: O objetivo deste trabalho foi avaliar a influência do Salivette poliéster na determinação das concentrações salivares de sIgA e alfa-amilase. Métodos: Foram coletadas amostras de saliva de 15 adultos jovens com bom estado de saúde, livres de infecções e mucosa bucal íntegra. Cada amostra de saliva foi dividida em duas porções: uma foi colocada sobre o poliéster do Salivette e a outra foi mantida no frasco original (controle), todas foram centrifugadas e armazenadas a -80ºC até a análise laboratorial. Resultados: As amostras salivares passadas pelo Salivette mostraram uma redução estatisticamente significante da concentração de sIgA, com uma redução de 17,3%±15,2, porém esta diferença não foi significante para as concentrações de alfa-amilase (p<0,05). Conclusão: A utilização do Salivette poliéster para coleta de saliva não influencia a concentração de alfa-amilase, porém altera de forma significante os níveis de sIgA.


Introduction: Human saliva has been widely used to quantify biomarkers for research and diagnostic purposes, once its collection is simple, non-invasive and stress-free. Although Salivette is the most used saliva collection device, due to its practicality and patient acceptance, the influence of its polyester version on the analysis of the salivary concentrations of some substances is unknown. Objective: This study aimed to assess the influence of polyester Salivette on the salivary concentrations of secretory immunoglobulin-A (s-IgA) and alpha-amylase. Methods: Salivary samples from 15 young adults, in good general health, free from infections and with a healthy oral mucosa, were collected. Each salivary sample was divided in two portions: one was placed on the Salivette polyester and the other was kept in the original flask (control). The samples were centrifuged and stored at -80ºC, until laboratory analysis was performed. Results: The salivary samples which had contact with Salivette showed a statistically significant reduction of s-IgA (17.3%±15.2). The difference was not significant for alpha-amylase (p<0.05). Conclusion: The polyester Salivette collection device does not influence alpha-amylase concentrations, but significantly reduces s-IgA levels.


Asunto(s)
Humanos , Saliva/química , Inmunoglobulina A/análisis , alfa-Amilasas/análisis , Óxido Nítrico
11.
Odonto (Säo Bernardo do Campo) ; 17(34): 49-55, jul.-dez. 2009. tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-542866

RESUMEN

Objetivo: verificar a associação entre disfunção temporomandibular (DTM) e alguns fatores oclusais, avaliando se a presença de contatos oclusais no lado de balanceio e/ou de discrepância entre relação centrica e máxima intercuspidação habitual maior que 2mm tem correlação significativa com a DTM. Além disso, pretendeu-se verificar se existia diferença de gênero entre os grupos e qual era a média de idade para o grupo de pacientes com DTM. Material e Métodos: a amostra foi constituída por 103 pacientes voluntários com idade entre 19 e 54 anos, provenientes das clínicas da Faculdade de Odontologia da Universidade Federal de Juiz de Fora. Os pacientes foram divididos em dois grupos: Grupo 1 - Controle: 52 pacientes não portadores de DTM; Grupo 2 - Teste: 51 pacientes portadores de DTM. Dois examinadores faziam o diagnóstico de DTM por meio do eixo I do protocolo RDC e a avaliação oclusal. Resultados: a presença de contatos oclusais no lado de balanceio e/ou de discrepância da posição de relação cêntrica e máxima intercuspidação habitual maior que 2mm não tem correlação estatisticamente significante com a disfunção temporomandibular. A média de idade no grupo teste foi de 25,88 anos e a diferença do número de mulheres entre os grupos estudados foi estatisticamente significativa. Conclusão: os fatores oclusais estudados não têm associação com a disfunção temporomandibular. Além disto, verificou-se que mulheres com idade próxima a 25 anos são mais acometidas por disfunção temporomandibular.


Objective: to verify the association between temporomandibular disorders and occlusal factors, evaluating if the presence of non-working side contacts and/or the difference between the values of retruded contact position to intercuspal position occlusal slides than 2mm have significant statistically correlation with the temporomandibular disorder. Besides, was intended to verify the difference between the test and control groups for the gender, and the age mean for the temporomandibular disorder’s patients. Material and Methods: the sample was constituted by 103 voluntary patients with age between 19 and 54 years, proceeding from the clinics of Faculdade de Odontologia da Universidade Federal de Juiz de Fora. The patients had been divided in two groups: Group 1 - Control: 52 patients without DTM; Group 2 - Test: 51 patients with DTM. Two examiners made the diagnosis of DTM through protocol RDC (axis I) and the occlusal evaluation. Results: the presence of non-working side contacts and/or the difference between the values of retruded contact position to intercuspal position occlusal slides than 2mm don’t have significant statistically correlation with the temporomandibular disorder. The mean age for the test group was 25,88 years and the difference between the women’s amount was significant statistically. Conclusion: occlusal factors have no association with temporomandibular disorders; and women and patients with age near 25 years was more attacked by temporomandibular disorder.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Oclusión Dental Céntrica , Trastornos de la Articulación Temporomandibular/epidemiología , Trastornos de la Articulación Temporomandibular/etiología , Brasil/epidemiología , Distribución de Chi-Cuadrado
12.
Rev. odontol. UNESP (Online) ; 38(5): 280-285, set.-out. 2009. tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-874788

RESUMEN

O objetivo deste trabalho foi avaliar: a) a correlação entre fatores oclusais - como trespasse vertical e horizontal, presença de contato oclusal no lado de balanceio e discrepância de relação cêntrica para máxima intercuspidação habitual - com o diagnóstico de disfunção temporomandibular (DTM); b) a diferença entre o grupo teste e o grupo controle para a variável gênero, e c) a média de idade para o grupo de pacientes com DTM. A amostra foi constituída por 103 pacientes voluntários, sem distinção de raça e gênero, com idade entre 19 e 54 anos. Os pacientes selecionados foram divididos em grupo controle (n = 52) e grupo teste (n = 51) com diagnóstico de DTM. Os critérios de inclusão foram relacionados ao diagnóstico de disfunção temporomandibular, baseado no eixo I do protocolo RDC/TMD. O exame clínico e as mensurações foram realizados por dois examinadores previamente calibrados (Cohen kappa = 0.85). Para comparar a diferença entre as variáveis, do grupo teste e do grupo controle, utilizou-se o teste Qui-quadrado (p-valor < 0,05). Os parâmetros de trespasse vertical (p-valor = 0,054), trespasse horizontal (p-valor = 0,811), contato oclusal no lado de balanceio (p-valor = 0,271) e discrepância entre relação cêntrica e máxima intercuspidação habitual (p-valor = 0,146) foram negativamente associadas à disfunção temporomandibular. A média de idade no grupo teste foi de 25,88 anos e a diferença do número de mulheres entre os grupos estudados foi estatisticamente significativa. Concluiu-se que os fatores oclusais avaliados neste estudo não apresentaram associação com a disfunção temporomandibular.


The purpose of this study was evaluate: the correlation between occlusal factors like increased overbite and overjet, presence of non-working side contacts and discrepancy of retruded contact position to intercuspal position occlusal slides with clinic manifestation of temporomandibular disorders. The sample was formed of 103 voluntary patients, without distinction of race or gender, with age between 19 and 54 years. The select patients was divided in control (n = 52) and test (n = 51) groups. The inclusion criteria was related to the temporomandibular disorders diagnostic, based on the Protocol RDC/TMD, axis I. The clinical exams and mensurations was performed by two calibrated examiners (Cohen kappa = 0.85). The Chi-square test (p-value < 0.05) was used to compare the difference between the variables of the test and control groups. The variables: overbite (p-value = 0.054), overjet (p-valor = 0.811), presence of non-working side contacts (p-valor = 0.271) and discrepancy of retruded contact position to intercuspal position occlusal slides (p-valor = 0.146) had no association with temporomandibular disorder. The mean age for the test group was 25.88 years and the difference between the women's amount was signifcant statistically. It was conclude that the occlusal factors have no association with temporomandibular disorders.


Asunto(s)
Humanos , Masculino , Femenino , Maloclusión , Oclusión Dental , Trastornos de la Articulación Temporomandibular , Distribución de Chi-Cuadrado
13.
Rev. odonto ciênc ; 24(3): 254-257, July-Sept. 2009. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-873874

RESUMEN

Purpose: This study investigated if abnormal vertical (overbite) and/or horizontal (overjet) dental overlap are more prevalent in adult subjects with clinical signs of temporomandibular disorders (TMD). Methods: Case-control design. The sample comprised 103 subjects, males and females from 19 to 54 year-old, which were divided into two groups: Group 1 (control) without TMD (n=52) and Group 2 (cases) with TMD (n=51). Inclusion criteria for Group 2 were based on axis I of the RDC/TMD protocol. Two calibrated examiners (Cohen kappa = 0.85) performed the clinical examination to collect data on occlusion and TMD. Data were analyzed by Chi-square tests. Results: Overbite mean values were 3.4 mm (control group) and 2.5 mm (cases group). Abnormal overbite was found in 26 subjects (50%) of the control group and 16 (31%) in the cases group (P=0.054). Overjet mean values were 2.4 mm and 2.0 mm for the control and cases groups, respectively. Abnormal overjet was found in 44 (85%) subjects of the control group and 44 (86%) of the cases group (P=0.811). No significant overall association was found between the tested occlusal variables and TMD (P=0.585). Conclusion: Overbite and overjet were not associated with TMD in this sample.


Objetivo: Este estudo investigou se anormalidades de trespasse vertical (overbite) e/ou horizontal (overjet) são mais prevalentes em sujeitos adultos com manifestações clínicas de desordens temporomandibulares (DTM). Metodologia: Desenho de caso-controle. A amostra consistiu de 103 sujeitos, com idades de 19 a 54 anos, que foram divididos em dois grupos: Grupo 1 (controle) sem DTM (n=52) e Grupo 2 (casos) com DTM (n=51). Os critérios de inclusão para o Grupo 2 basearam-se no eixo I do protocolo RDC/TMD. Dois examinadores calibrados (Cohen kappa = 0.85) realizaram o exame clínico para coleta dos dados de oclusão e de DTM. Data were analyzed by Chi-square tests.Resultados: Os valores médios de overbite foram 3,4 mm (controle) e 2,5 mm (casos). Overbite anormal foi mensurado em 26 sujeitos (50%) do grupo controle e 16 (31%) no grupo casos (P=0,054). Os valores médios de overjet foram de 2,4 mm e 2,0 mm para os grupos controle e casos, respectivamente. Observou-se overjet anormal em 44 (85%) sujeitos do grupo controle e 44 (86%) dos casos (P=0,811). Nenhuma associação significativa foi observada entre as variáveis oclusais testadas e DTM (P=0,585).Conclusão: Overbite e overjet não foram associadas a DTM nesta amostra.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Oclusión Dental , Síndrome de la Disfunción de Articulación Temporomandibular , Estudios de Casos y Controles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...